Enter a new password. Casella CEL. Apex personal sampling pump. Preparation Please refer to warnings and operation section of HB before using I. Display Symbols Halt - shows when pump is in Hold Mode, or blinks when halt option available.
Run - shows when pump motor is running. Flow - indicates real flow monitoring. Warning - indicates flow outside permitted limits or other error conditions.
Hold Mode When the instrument is switched ON but the pump is not operating, nor a program being executed, it is in Hold Mode where the display cycles between: TIME Accumulated sample time since the instrument was last reset. A soon as CAL SEt is displayed, use and to adjust the actual flow measured by the flow tube to match the set point, then press to accept the value.
Configuration Mode This mode allows basic settings to be changed. Use or to change between: OFF , no buzzer, Err , any error sounds an alarm, On , any error or key press sounds an alarm. Use or to change between: ON with the program features available, OFF with the program features hidden. To stop sampling while the pump is in Run Mode, press and hold until the symbol stops blinking and disappears. Flow Restriction If the input flow is restricted, both and the Red LED will flash and when activated the buzzer sound to indicate a problem.
Stop the pump and disconnect the flowmeter. Perform the measurements using a fresh sorbent tube. Bag Mode This allows the pump to fill a gas bag and stop automatically when the bag is full. You can only view or download manuals with. Sign Up and get 5 for free. Upload your files to the site. You get 1 for each file you add. Get 1 for every time someone downloads your manual. Buy as many as you need. View and download manuals available only for. Register and get 5 for free. Upload manuals that we do not have and get 1 for each file.
Previous Page. Next Page. Page 3 Apex2 Language Page 4 Apex2 Technical specifications If a fault is suspected, return the pump to Casella or a Casella approved service centre.
CAUTION If the equipment is likely to come into contact with aggressive substances, take precautions to prevent the instrument from being adversely affected, so that the type of protection is not compromised. Page 7: Disclaimer Whilst every care is taken to ensure that the information in this manual is correct, Casella will assume no responsibility for loss, damage or injury caused by any errors in, or omissions Page 8: Introduction A gauge shows the battery charge level, and on Pro and Plus models, the remaining run time.
The following table summarises the features and capabilities of the Apex 2 range of pumps. Page 9: Controls And Fittings Apex2 Controls and fittings The Apex 2 has a limited number of easy to use controls and two pipe fittings. Page Tube Connections Apex2 Tube connections Sampling inlet connection Connect the collection head tube to the inlet nozzle on the pump Gas bag outlet connection When using the pump to collect gas, connect the gas bag tube to the pump outlet using the supplied Luer fitting.
Page Operation Apex2 Operation This section describes how to use the pump to take air samples using the minimum of settings. The Apex2 has many other menu and settings options and these are described in later chapters.
Check the battery level, which will show either a percentage when the pump is not running or number of hours remaining when the pump is running except Apex2 Standard which will show percentage. Reset the data Use this menu item to reset the accumulated run time, motion index and volume data to zero.
If you want to start a timed sampling run see page To start a sampling run: Turn on the pump. Page Full Lock Apex2 Full lock The full lock can only be set when the pump is running and is denoted by a closed padlock icon.
While fully locked, the keypad is fully de-activated. The wearer cannot stop or disturb the pump by any key presses. These may be used to define daily or weekly sampling sequences. To set up the run sequence, see Sequencer on page Page Settings This section describes the settings you may wish, or need, to alter occasionally, and it describes how to access system information you may be asked for by a service technician.
Inspiron 2H, 2. Mazda Automobile Quick tips File: mazda-mazdaquick-tips, 16th Jun Mazda 5, Cadence , All Versions: Apex and Apex Pro air sampling pumps are designed to be robust, however they should not be dropped or subjected to mechanical shock.